Lung mechanics and high-resolution computed tomography of the chest in very low birth weight premature infants

Descargar SCORM

Este recurso ha sido solicitado 1 veces (0 veces en los últimos 31 días).

Para poder solicitar este recurso debe identificarse como usuario de la biblioteca

 
Ver

Detalles del recurso

Marcadores Sociales
Lung mechanics and high-resolution computed tomography of the chest in very low birth weight premature infants
Id. 634489
Idioma inglés
Titulo Lung mechanics and high-resolution computed tomography of the chest in very low birth weight premature infants
Autor(es) Mello,Rosane Reis de
Dutra,Maria Virgínia Peixoto
Ramos,José Roberto
Daltro,Pedro
Boechat,Márcia
Lopes,José Maria de Andrade
Localización http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-31802003000400006
Versión 1.0
Estado Final
Descripción CONTEXT: Premature infant lung development may be affected by lung injuries during the first few weeks of life. Lung injuries have been associated with changes in lung mechanics. OBJECTIVE: To evaluate an association between lung mechanics and lung structural alterations in very low birth weight infants (birth weight less than 1500 g). DESIGN: A cross-sectional evaluation of pulmonary mechanics (lung compliance and lung resistance) and high resolution computed tomography of the chest at the time of discharge, in 86 very low birth weight infants born at Instituto Fernandes Figueira, a tertiary public healthcare institution in Rio de Janeiro, Brazil. Lung compliance and resistance were measured during quiet sleep. High resolution computed tomography was performed using Pro Speed-S equipment. MAIN MEASUREMENTS: Statistical analysis was performed by means of variance analysis (ANOVA/ Kruskal Wallis). The significance level was set at 0.05. RESULTS: Abnormal values for both lung compliance and lung resistance were found in 34 babies (43%), whereas 20 (23.3%) had normal values for both lung compliance and lung resistance. The mean lung compliance and lung resistance for the group were respectively 1.30 ml/cm H2O/kg and 63.7 cm H2O/l/s. Lung alterations were found via high-resolution computed tomography in 62 (72%) infants. Most infants showed more than one abnormality, and these were described as ground glass opacity, parenchymal bands, atelectasis and bubble/cyst. The mean compliance values for infants with normal (1.49 ml/cm H2O/kg) high resolution computed tomography, 1 or 2 abnormalities (1.31 ml/cm H2O/kg) and 3 or more abnormalities (1.16 ml/cm H2O/kg) were significantly different (p = 0.015). Our data were insufficient to find any association between lung resistance and the number of alterations via high-resolution computed tomography. CONCLUSION: The results show high prevalence of lung functional and tomographic abnormalities in asymptomatic very low birth weight infants at the time of discharge. They also show an association between lung morphological and functional abnormalities.
Tipo text/html
Palabras clave Premature infant
Tipo de recurso journal article
Tipo de Interactividad Expositivo
Nivel de Interactividad muy bajo
Audiencia Estudiante
Profesor
Autor
Estructura Atomic
Coste no
Copyright
Formatos text/html
Requerimientos técnicos Browser: Any
Fecha de contribución 23-may-2005
Contacto

Valoración de los usuarios

No hay ninguna valoración para este recurso. Sea el primero en valorar este recurso.