A new dynamic myocardial phantom for the assessment of left ventricular function by gated single-photon emission tomography.
Kubo, Naoki Morita, Koichi Katoh, Chietsugu Shiga, Tohru Konno, Masanori Tsukamoto, Eriko Morita, Yutaka Tamaki, Nagara
Location:
http://hdl.handle.net/2115/14887
European Journal of Nuclear Medicine and Molecular Imaging. 27(10), 2000, 1525-1530
http://dx.doi.org/10.1007/s002590000318
Gated myocardial perfusion single-photon emission tomography (SPET) has been used for the measurement of left ventricular (LV) function and validated by means of comparison with other imaging modalities. We have designed a new dynamic myocardial phantom in order to validate the LV function as assessed by the use of gated myocardial perfusion SPET. The phantom consists of two half-ellipsoids (an endocardial surface and an epicardial surface) and a thorax. The myocardial space is filled with a radioactive solution. The endocardial surface moves continuously towards and away from the epicardial surface in the longitudinal axis to vary the LV volume [143 ml at end-diastole (ED), 107 ml at end-systole (ES)] and thickness (apex 8 mm at ED and 26 mm at ES, midplane 8 mm). The mean values of wall motion (WM) for the apical midplane region and the basal midplane region were 5 mm and 2 mm, respectively. Gated myocardial SPET was performed during 8 and 16 intervals. These projection data sets were processed using a Butterworth filter with an order of 5 and a critical frequency of 0.34 cycles/cm. LV function was calculated using the quantitative gated SPET (QGS) algorithm. The LV function values estimated by gated SPET during 16 intervals [22% for ejection fraction (EF), 3.7 mm for WM of the apical midplane, 1.7 mm for WM of the basal midplane] closely resembled actual LV functions [25% for EF, 5 mm for WM of the apical midplane, 2 mm for WM of the basal midplane]. However, the estimated values during 8 intervals were smaller than those during 16 intervals (19% for EF, 3.3 mm for WM of the apical-midplane, 1.1 mm for WM of the basal-midplane). The estimated LV volumes closely correlated with the actual volumes (r=0.99 for 16 intervals, r=0.95 for 8 intervals). Utilizing this phantom, LV function estimated using gated myocardial SPET can be compared with actual values.
Belongs to: Hokkaido University Collection of Scholarly and Academic Papers
Descargar SCORM
¡Sea el primero en solicitar este recurso!
Para poder solicitar este recurso debe identificarse como usuario de la biblioteca
Users rating
No hay ninguna valoración para este recurso. Sea el primero en
valorar este recurso.
Detalles del recurso
|
A new dynamic myocardial phantom for the assessment of left ventricular function by gated single-photon emission tomography.
|
| Id. |
13249733 |
| Idioma |
inglés
|
| Titulo |
A new dynamic myocardial phantom for the assessment of left ventricular function by gated single-photon emission tomography. |
| Autor(es) |
Kubo, Naoki Morita, Koichi Katoh, Chietsugu Shiga, Tohru Konno, Masanori Tsukamoto, Eriko Morita, Yutaka Tamaki, Nagara |
| Location |
http://hdl.handle.net/2115/14887
European Journal of Nuclear Medicine and Molecular Imaging. 27(10), 2000, 1525-1530
http://dx.doi.org/10.1007/s002590000318
|
| Versión |
1.0 |
| Estado |
Final
|
| Descripción |
Gated myocardial perfusion single-photon emission tomography (SPET) has been used for the measurement of left ventricular (LV) function and validated by means of comparison with other imaging modalities. We have designed a new dynamic myocardial phantom in order to validate the LV function as assessed by the use of gated myocardial perfusion SPET. The phantom consists of two half-ellipsoids (an endocardial surface and an epicardial surface) and a thorax. The myocardial space is filled with a radioactive solution. The endocardial surface moves continuously towards and away from the epicardial surface in the longitudinal axis to vary the LV volume [143 ml at end-diastole (ED), 107 ml at end-systole (ES)] and thickness (apex 8 mm at ED and 26 mm at ES, midplane 8 mm). The mean values of wall motion (WM) for the apical midplane region and the basal midplane region were 5 mm and 2 mm, respectively. Gated myocardial SPET was performed during 8 and 16 intervals. These projection data sets were processed using a Butterworth filter with an order of 5 and a critical frequency of 0.34 cycles/cm. LV function was calculated using the quantitative gated SPET (QGS) algorithm. The LV function values estimated by gated SPET during 16 intervals [22% for ejection fraction (EF), 3.7 mm for WM of the apical midplane, 1.7 mm for WM of the basal midplane] closely resembled actual LV functions [25% for EF, 5 mm for WM of the apical midplane, 2 mm for WM of the basal midplane]. However, the estimated values during 8 intervals were smaller than those during 16 intervals (19% for EF, 3.3 mm for WM of the apical-midplane, 1.1 mm for WM of the basal-midplane). The estimated LV volumes closely correlated with the actual volumes (r=0.99 for 16 intervals, r=0.95 for 8 intervals). Utilizing this phantom, LV function estimated using gated myocardial SPET can be compared with actual values. |
| Tipo |
1341447 bytes application/pdf |
| Palabras clave |
Myocardium |
| Tipo de recurso |
article (author version)
|
| Tipo de Interactividad |
Expositivo
|
| Nivel de Interactividad |
muy bajo
|
| Audiencia |
Estudiante
Profesor
Autor
|
| Estructura |
Atomic |
| Coste |
no
|
| Copyright |
sí
|
|
The original publication is available at www.springerlink.com |
| Formatos |
1341447 bytes application/pdf |
| Requerimientos técnicos |
Browser: Any |
| Fecha de contribución |
26-oct-2007 |
| Contacto |
|
|