Reconstruction of Sphenoid Wing Dysplasia with Pulsating Exophthalmos in a Case of Neurofibromatosis Type 1 Supported by Intraoperative Navigation Using a New Skull Reference System
|
Descargar SCORM
¡Sea el primero en solicitar este recurso!
Para poder solicitar este recurso debe identificarse como usuario de la biblioteca
|
| |
Ver
Detalles del recurso
|
|
|
Reconstruction of Sphenoid Wing Dysplasia with Pulsating Exophthalmos in a Case of Neurofibromatosis Type 1 Supported by Intraoperative Navigation Using a New Skull Reference System
|
| Id. |
18097846 |
| Idioma |
inglés
|
| Titulo |
Reconstruction of Sphenoid Wing Dysplasia with Pulsating Exophthalmos in a Case of Neurofibromatosis Type 1 Supported by Intraoperative Navigation Using a New Skull Reference System |
| Autor(es) |
Friedrich, Reinhard E. Heiland, Max Kehler, Uwe Schmelzle, Rainer |
| Localización |
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=1131854
|
| Versión |
1.0 |
| Estado |
Final
|
| Descripción |
A patient with neurofibromatosis type 1 had pulsating exophthalmos of the right eye with diplopia resulting from severe dysplasia of the sphenoid bone and consecutive herniation of the right temporal lobe. The right orbital tectum was reconstructed with titanium mesh and iliac spongiosa via a lateral orbitotomy using intraoperative navigation. For intraoperative referencing a cortical fixedreference system and a skin scanning laser device were used. Postoperatively, the diplopia was reduced, but the patient asked for further treatment and the procedure was repeated 6 months later. Intraoperatively, the previously implanted titanium mesh was deformed and most of the transplanted bone was resorbed, probably because of pressure. A more extended mesh was implanted and iliac spongiosa was placed on both sides. Intraoperative navigation was used during both procedures. The adverse effects of diplopia were minimized and followup computed tomography after seven months confirmed that the bone graft was in place. |
| Palabras clave |
Case Report |
| Tipo de recurso |
Text
|
| Tipo de Interactividad |
Expositivo
|
| Nivel de Interactividad |
muy bajo
|
| Audiencia |
Estudiante
Profesor
Autor
|
| Estructura |
Atomic |
| Coste |
no
|
| Copyright |
sí
|
|
Copyright © 2003 by Thieme Medical Publishers, Inc., 333 Seventh Avenue, New York, NY 10001, USA |
| Requerimientos técnicos |
Browser: Any |
| Fecha de contribución |
04-mar-2008 |
| Contacto |
|
|
|
|
|
Valoración de los usuarios
No hay ninguna valoración para este recurso. Sea el primero en
valorar este recurso.
|
|
|
|