1) La descarga del recurso depende de la página de origen
2) Para poder descargar el recurso, es necesario ser usuario registrado en Universia


Opción 1: Descargar recurso

Detalles del recurso

Descripción

[EN] This paper presents an energy performance evaluation of two low-GWP refrigerants, R1234yf and R1234ze(E), as drop-in replacements for R134a. Tests are carried out in a monitored vapor compression system combining different values of evaporation and condensation temperature, and without/with the adoption of an internal heat exchanger. The parameters analyzed are volumetric efficiency, cooling capacity and COP and they are presented taking R134a as baseline. Results show that without IHX the average volumetric efficiency for R1234yf and R1234ze is 4% and 5% lower compared with R134a. The cooling capacity obtained with R1234yf and R1234ze is reduced, with an average difference of 9% and 30% without IHX. Also, COP values are about 7% lower for R1234yf and 6% lower for R1234ze than those obtained using R134a. Finally, the use of an internal heat exchanger reduces the COP differences for both replacements. (C) 2014 Elsevier Ltd. All rights reserved.

Pertenece a

RiuNet. Repositorio institucional de la Universitat de Valencia  

Autor(es)

Mota -  Babiloni, Adrián -  Navarro -  Esbrí, J. -  BARRAGÁN CERVERA, ÁNGEL -  Molés, Francisco -  Peris, Bernardo - 

Id.: 70961718

Idioma: eng  - 

Versión: 1.0

Estado: Final

Palabras claveDrop -  in - 

Tipo de recurso: info:eu-repo/semantics/article  -  info:eu repo/semantics/publishedVersion  - 

Tipo de Interactividad: Expositivo

Nivel de Interactividad: muy bajo

Audiencia: Estudiante  -  Profesor  -  Autor  - 

Estructura: Atomic

Coste: no

Copyright: sí

: Reserva de todos los derechos

Requerimientos técnicos:  Browser: Any - 

Relación: [References] MINISTERIO DE EDUCACION /AP2012-2841
[References] Applied Thermal Engineering
[References] https://doi.org/10.1016/j.applthermaleng.2014.06.056

Fecha de contribución: 03-feb-2018

Contacto:

Localización:
* 1359-4311
* 10.1016/j.applthermaleng.2014.06.056

Otros recursos de la mismacolección

  1. Estimación de un indicador de la resistencia de los acuíferos españoles a las sequías [ES] Las descargas de las aguas subterráneas a los ríos y manantiales son función de las recargas y ...
  2. Applied tools to support Júcar management decisions during 2005-2007 drought [EN] Droughts in arid and semiarid Mediterranean basins have an increasing socioeconomic and environ...
  3. Importación y exportación de los datos de EPANET al entorno gvSIG con el módulo de programación v2.1 [EN] The application EPAgvSIG is intended to integrate in a free GIS the main capabilities of the wo...
  4. Estudio de los problemas de bioensuciamiento de membranas y espumas de origen biológico en sistemas MBR de tratamiento de lixiviados Alonso Molina, JL.; Moreno Trigos, MY.; Zuriaga Agusti, E.; Moreno-Mesonero, L.; Amoros, I.; Fernánd...
  5. Filtration process cost in submerged anaerobic membrane bioreactors (AnMBRs) for urban wastewater treatment [EN] The objective of this study was to evaluate the effect of the main factors affecting the cost o...

Aviso de cookies: Usamos cookies propias y de terceros para mejorar nuestros servicios, para análisis estadístico y para mostrarle publicidad. Si continua navegando consideramos que acepta su uso en los términos establecidos en la Política de cookies.