Publicidad

Publicidad

becas.universia.netBiblioteca.Net

Buscar recursos:

Buscador Google

rss_1.0 Clasificación por Disciplina

Nomenclatura Unesco > (32) Ciencias Médicas > (3204) Medicina del trabajo > (3204.01) Medicina nuclear

Categorías relacionadas:
(2418) Radiobiología (3207.15) Patología de la radiación

Mostrando recursos 1 - 20 de 759

1. Intercomparação e calibração de medidores de atividade utilizados em serviços de medicina nuclear - Costa,Alessandro Martins da; Caldas,Linda V.E.
OBJETIVO: O objetivo deste trabalho foi estabelecer um padrão de trabalho para intercomparação e calibração de medidores de atividade (calibradores de dose) utilizados na maioria dos serviços de medicina nuclear, para determinação da atividade dos radionuclídeos administrados aos pacientes nos exames específicos ou nos procedimentos terapêuticos. MATERIAIS E MÉTODOS: Foi utilizado um calibrador de dose comercial, um conjunto de fontes radioativas padrões, além de seringas, frascos e ampolas contendo soluções de radionuclídeos utilizados em medicina nuclear. RESULTADOS: O calibrador de dose comercial foi calibrado com soluções de radionuclídeos utilizados em medicina nuclear. Os testes simples do instrumento, tais como o...

2. Proposta de método de inspeção de radioproteção aplicada em instalações de medicina nuclear - Mendes,Leopoldino da Cruz Gouveia; Fonseca,Léa Mirian Barbosa da; Carvalho,Antonio Carlos Pires
O objetivo principal deste trabalho é implantar um método de inspeção imparcial e eficiente, visando à utilização segura e correta das radiações ionizantes no campo da medicina nuclear. Este método de inspeção aqui proposto foi aplicado em 113 serviços de medicina nuclear do país, obedecendo a uma freqüência de análise bienal (1996, 1998, 2000 e 2002). Foram estabelecidos 82 itens de radioproteção com pesos para cada item, baseados nos fatores de risco, de acordo com as normas da Comissão Nacional de Energia Nuclear (CNEN) e as recomendações da Agência Internacional de Energia Atômica. Na análise do serviço, cada item de...

3. Avaliação da influência do percentual de marcação do 99mTc-MIBI em procedimentos de medicina nuclear em Recife - Jucilene Maria Pereira
O objetivo deste trabalho foi avaliar a influência do percentual de marcação do radiofármaco99mTc-MIBI nos procedimentos adotados em serviços de medicina nuclear em Recife e a suapossível interferência na qualidade da imagem produzida durante o exame de perfusão demiocárdio. Este trabalho foi realizado em dois serviços de medicina nuclear do Recife queutilizam o fármaco MIBI provenientes de dois diferentes fabricantes: o Cardiolite, fabricadopela DUPONT e o Cardiosyd, fabricado pela SYDMA. O pH, percentual de marcação eestabilidade de amostras do 99mTc-MIBI e o percentual de captação no coração de um númerode pacientes foram avaliados. Os resultados mostraram que os valores de...

4. Estudio de los parámetros de calibración de activímetros en medicina nuclear - Cárdenas Solano, Alexander Jesús
El presente trabajo de Tesis realizado en el Departamento de Medicina Nuclear en el Instituto Nacional de Enfermedades Neoplásicas INEN, tiene como objetivo estudiar los diferentes parámetros de calibración de los Activímetros como: Precisión, exactitud, linealidad, estabilidad, sensibilidad y reproducibilidad ajustados debidamente con sus factores de calibración y factores de geometría, previamente hallados para cada fuente de referencia y radioisótopos más usados en el departamento. Este estudio se realizó con el fin de poder garantizar la eficacia y confiabilidad del equipo al momento de medir la actividad del radioisótopo, ya que el incorrecto funcionamiento de un Activímetro conduce a la...

5. Compendio de medicina nuclear para alivio de estudiantes / Carlos Chalbaud Zerpa - Chalbaud Zerpa, Carlos; Universidad de Los Andes. Facultad de Medicina, Tesis, 1968
Incluye bibliografía e índice

6. Avaliação dos efeitos do extrato etanolico de Curatella americana sobre a marcação de elementos sanguineos com tecnecio 99M e na sobrevivencia de cultura bacteriana - Fernanda Rocha Soares
O tecnécio 99-m (Tc-99m), na forma de pertecnetato de sódio (Na99"'Tc04), é um radiofármaco empregado em avaliações clínicas da medicina nuclear. A Curatella americana é uma planta de cerrado cuja parte utilizada é a casca do caule com uso antiulcerogênico. Tem sido descrito que a interação de drogas altera a biodistribuição dos radiofármacos, bem como sua ligação aos elementos sangüíneos ou a outras moléculas, o que pode alterar diagnósticos usando radiofármacos. Portanto, para contribuir com o estudo de como outras substâncias podem interferir na marcação do Tc-99m e também com a finalidade de elucidar efeitos biológicos in vitro, foram estudados...

7. Annals of Nuclear Medicine

8. BMC Nuclear Medicine

9. Nuclear medicine in tropical diseases - Braga,Francisco José Hossri Nogueira
Tropical diseases affect more people in the world than any other kind of disease, but scintigraphic data on that matter are not so frequent in the literature. Since the geographic regions where such diseases occur are normally very poor, scintillation cameras may not be available. We present a resumed summary of part of what has been done on this subject to-date. Leprosy affects circa 12 million people worldwide and has already been studied by means of the following scintigraphic exams: Gallium-67, 99mTc-MDP or HMDP, 99mTc-colloid or Dextran, 99mTc-DTPA and 99mTc-WBC. Paracoccidiodomycosis is a deep mycosis and such cases may be...

10. Fratura de estresse e a medicina nuclear - Kempfer,Gérson Luís; Figueiredo,Andrea Bruno; Macedo,Sandro Tadeu; Rocha,Antonio Fernando Gonçalves da
Os autores apresentam um caso de fratura de estresse detectada pela Medicina Nuclear, com breve revisão bibliográfica dos métodos de imagem aplicados no diagnóstico e seguimento desta patologia.

11. Wavelet Domain Filtering for Nuclear Medicine Imaging - Robert D. Nowak,David J. Nowak,Richard G. Baraniuk,Robert S. Hellman
We propose a new filtering/estimation method for nuclear medicine imaging. The statistical method of crossvalidation is used to design optimal wavelet domain filters for improved image estimation. The quality of the resulting images is much better than standard image estimates, in both visual and mean square error senses. Moreover, experiments have shown that, using the new estimate, we can reduce the acquisition time by a factor of two and still retain high image quality. I. Introduction This paper reports on the development of a new waveletbased filtering algorithm for nuclear medicine imaging. Wavelet-based filtering is a relatively recent advance in digital signal processing (DSP) [1]. Wavelet-based filtering offers significant theoretical advantages over classical linear...

12. Java-based PACS and reporting system for Nuclear Medicine - Piotr J Slomka,Edward Elliott,Albert A Driedger
In medical imaging practice, images and reports often need be reviewed and edited from many locations. We have designed and implemented a Java-based Remote Viewing and Reporting System (JaRRViS) for a nuclear medicine department, which is deployed as a web service, at the fraction of the cost of dedicated PACS systems. The system can be extended to other imaging modalities. JaRRViS interfaces to the clinical patient databases of imaging workstations. Specialized nuclear medicine applets support interactive displays of data such as 3-D gated SPECT with all the necessary options such as cine, filtering, dynamic lookup tables, and reorientation. The reporting module is implemented as a separate...

13. Contribuição da medicina nuclear para a avaliação dos linfomas - Sapienza,Marcelo T.; Marone,Marília M. S.; Chiattone,Carlos S.
A medicina nuclear permite a caracterização funcional de tecidos, acrescentando dados à avaliação anatômica realizada por outros métodos de imagem, como a tomografia computadorizada, ressonância magnética ou ultra-som. Além do diagnóstico e estadiamento, as informações funcionais fornecidas pela medicina nuclear são particularmente úteis no seguimento e avaliação de resposta terapêutica dos pacientes com linfoma. A presença de massa residual após quimioterapia ou a infiltração de linfonodos de pequenas dimensões são exemplos de situações nas quais a avaliação isolada de características anatômicas é insuficiente. Os principais métodos utilizados são a cintilografia com gálio-67, traçador com alta afinidade por transferrina e receptores...

14. Nuclear Medicine - Antonia Dimitrakopouloustrauss,Ludwig G. Strauss,Frank Gutzler,Gisela Irngartinger Md,George Kontaxakis Phd,Duk Kyu Kim,Franz Oberdorfer Phd,Carcinomas Whowere,Ethanol Injection
eight tumors. CONCLUSION: Inhomogeneous drug distribution and drug dilution in the target area are likely to be the major limiting parameters for therapy response. Percutaneous ethanol injection is used for curative or palliative treatment of hepatocellular carcinomas. Percutaneous ethanol injection is considered a reliable alternative to surgical resection for patients with cirrhosis and a single, small hepatocellular carcinoma (1). Major problems when using percutaneous ethanol injection are the assessment of the ethanol distribution in the target area and the noninvasive evaluation of early response. Morphologic imaging modalities, like ultrasonography, computed tomography (CT), or magnetic resonance (MR) imaging, have been used to determine the effect of percutaneous ethanol injection by using...

15. Gamagrama de la placenta : un aporte de la medicina nuclear al diagnóstico clínico / José N. Crespo Caruci - Crespo Caruci, José N.; Universidad de Los Andes. Facultad de Medicina, trabajo de ascenso, 1980
Trabajo de ascenso (Prof. Asistente)-- Universidad de Los Andes, Facultad de Medicina, Instituto de Medicina Nuclear, Mérida, 1980

16. Application of Joint Intensity Algorithms to the Registration of Emission Tomography and Anatomical Images
In current practice, it is common in medical diagnosis or treatment monitoring for a patient to require multiple examinations using different imaging techniques. Magnetic resonance (MR) imaging and computed tomography (CT) are good at providing anatomical information. Three-dimensional functional information about tissues and organs is often obtained with radionuclide imaging modalities: positron emission tomography (PET) and single photon emission tomography (SPET). In nuclear medicine, such techniques must contend with poor spatial resolution, poor counting statistics of functional images and the lack of correspondence between the distribution of the radioactive tracer and anatomical boundaries. Information gained from anatomical and functional images...

17. Avaliação da compressão com perdas em imagens cardiacas de medicina nuclear - Hamilton Monteiro
As técnicas de compressão de imagens tem como objetivo reduzir o volume de dados a serem armazenados ou transmitidos em sistemas digitais. A utilização de técnicas de compressão com perdas merece ser investigada, uma vez que as mesmas apresentam altas taxas de compressão, ainda que alterando o conteúdo de informação das imagens. Este trabalho estuda o efeito de aplicação da compressão com perdas em imagens cardíacas de medicina nuclear e a avalia a possibilidade de utilização dessas imagens no diagnóstico clínico. Foram estudadas 120 imagens, de pacientes normais e portadores de patologias cardíacas, que foram comprimidas/descomprimidas pela técnica da transformada...

18. A comparison of dose savings of lead and lightweight aprons for shielding of 99m-Technetium radiation - Warren-Forward, Helen; Cardew, Paul; Smith, Bradley; Clack, Llewellyn; McWhirter, Kym; Johnson, Stacey; Wessel, Kimberly
Nuclear medicine technologists (NMTs) have the highest effective doses of radiation among medical workers. With increase in the use of lightweight materials in diagnostic radiography, the aim was to compare the effectiveness of lead and lightweight aprons in shielding from 99m-Technetium (⁹⁹mTc) gamma rays. The doses received from a scattering phantom to the entrance, 9cm depth and exit of a phantom were measured with LiF:Mg, Cu, P thermoluminescent dosemeters (TLDs). Doses and spectra were assessed without no shielding, with 0.5-mm lead and lightweight aprons. The lead and lightweight aprons decreased entrance surface doses by 76 and 59%, respectively. The spectral...

19. Contador automático de actividad-tiempo / Alvaro Tucci R. - Tuccio R., Alvaro; Universidad de Los Andes.. Facultad de Medicina, Trabajo de ascenso, 1972
Mecanografiado

20. Fuente de alta tensión regulada U.L.A.-Lic 038 / Rómulo R. González B. - González B., Rómulo R.; Universidad de Los Andes.. Facultad de Medicina, Trabajo de ascenso, 1983
Mecanografiado

Página de resultados:
2  3  4  5  6  7  8  9  10  Siguiente